Mnemonic Signal Name Type Bits Units 1 2 3 4 5 6 Remarks
1CBAT Camera Body Temp. A PA 8 C Y Y Y Y Y Y +Z face of aluminum camera body. Part Number MF-118.
1CBBT Camera Body Temp. B PA 8 C Y Y Y Y Y Y -Z face of aluminum camera body. Part Number MF-118.
1CRAT Cold Radiator Temp. A PA 8 C Y Y Y Y Y Y Cold radiator +Y cold strap attach point. Part Number MF-118.
1CRBT Cold Radiator Temp. B PA 8 C Y Y Y Y Y Y Cold radiator -Y cold strap attach point. Part Number MF-118.
1DABOAEN DA Bake Out Enable A SD 1 Y Y Y Y Y Y 0=Disabled, 1=Enabled
1DABOAON DA Bake Out On/Off A SD 1 Y Y Y Y Y Y 0=Off, 1=On
1DABOBEN DA Bake Out Enable B SD 1 Y Y Y Y Y Y 0=Disabled, 1=Enabled
1DABOBON DA Bake Out On/Off B SD 1 Y Y Y Y Y Y 0=Off, 1=On
1DACTAT DA Collimator Temp. A PA 8 C Y Y Y Y Y Y +Z Mounting foot of titanium collimator. Part Number MF-118.
1DACTBT DA Collimator Temp. B PA 8 C Y Y Y Y Y Y +Y Mounting foot of titanium collimator. Part Number MF-118.
1DAHACU DA Heater Current A AA 8 A Y Y Y Y Y Y The current supplied to the DA heater A elements
1DAHAT DA Housing Temp. A Offset AA 8 C Y Y Y Y Y Y DA Housing Temperature Controller A error amplifier output. It is proportional to the difference of the setpoint temperature and actual temperature. This is located near the heater elements.
1DAHAVO DA Heater Voltage A AA 8 V Y Y Y Y Y Y The voltage output to the DA heater A elements
1DAHBCU DA Heater Current B AA 8 A Y Y Y Y Y Y The current supplied to the DA heater B elements
1DAHBT DA Housing Temp. B Offset AA 8 C Y Y Y Y Y Y DA Housing Temperature Controller B error amplifier output. It is proportional to the difference of the setpoint temperature and actual temperature. This is located near the heater elements.
1DAHBVO DA Heater Voltage B AA 8 V Y Y Y Y Y Y The voltage output to the DA heater B elements
1DAHHAVO DA Housing Heater Input Voltage A AA 8 V Y Y Y Y Y Y DA Housing Temperature Controller A input voltage
1DAHHBVO DA Housing Heater Input Voltage B AA 8 V Y Y Y Y Y Y DA Housing Temperature Controller B input voltage
1DAHTAEN DA Heater Enable/Disable A SD 1 Y Y Y Y Y Y 0=Disabled, 1=Enabled
1DAHTAON DA Heater On/Off A SD 1 Y Y Y Y Y Y 0=Off, 1=On
1DAHTBEN DA Heater Enable/Disable B SD 1 Y Y Y Y Y Y 0=Disabled, 1=Enabled
1DAHTBON DA Heater On/Off B SD 1 Y Y Y Y Y Y 0=Off, 1=On
1DE28AOC DEA Power Supply +28V Over-Current Protection A SD 1 Y Y Y Y Y Y DEA Power Supply Over-Current Protection A +28V output. 0=NO Overcurrent condition detected, 1=Overcurrent condition detected, OCP engaged, power converter shut off.
1DE28AVO DEA Input Voltage A AA 8 V Y Y Y Y Y Y The voltage supplied to the DEA +28V Input, Side A
1DE28BOC DEA Power Supply +28V Over-Current Protection B SD 1 Y Y Y Y Y Y DEA Power Supply Over-Current Protection B +28V output. 0=NO Overcurrent condition detected, 1=Overcurrent condition detected, OCP engaged, power converter shut off.
1DE28BVO DEA Input Voltage B AA 8 V Y Y Y Y Y Y The voltage supplied to the DEA +28V Input, Side B
1DEAMZT DEA -Z Panel Temp PA 8 C Y Y Y Y Y Y DEA -Z Panel Temp. Part Number 311P18-02S7R6.
1DEDBAON DEA Power Supply 28V ON A SD 1 Y Y Y Y Y Y 0=Buss has no power, 1=Buss has power
1DEDBBON DEA Power Supply 28V ON B SD 1 Y Y Y Y Y Y 0=Buss has no power, 1=Buss has power
1DEICACU DEA Input Current A AA 8 A Y Y Y Y Y Y The current supplied to the DEA +28V Input, Side A
1DEICBCU DEA Input Current B AA 8 A Y Y Y Y Y Y The current supplied to the DEA +28V Input, Side B
1DEMVAOC DEA Power Supply Multi-V Over-Current Protection A SD 1 Y Y Y Y Y Y DEA Power Supply Over-Current Protection A combined for all PS outputs. 0=NO Overcurrent condition detected, 1=Overcurrent condition detected, OCP engaged, power converter shut off.
1DEMVBOC DEA Power Supply Multi-V Over-Current Protection B SD 1 Y Y Y Y Y Y DEA Power Supply Over-Current Protection B combined for all PS outputs. 0=NO Overcurrent condition detected, 1=Overcurrent condition detected, OCP engaged, power converter shut off.
1DEN0AVO DEA -6V Voltage A AA 8 V Y Y Y Y Y Y The voltage supplied to the DEA -6V Input, Side A
1DEN0BVO DEA -6V Voltage B AA 8 V Y Y Y Y Y Y The voltage supplied to the DEA -6V Input, Side B
1DEN1AVO DEA -15V Voltage A AA 8 V Y Y Y Y Y Y The voltage supplied to the DEA -15V Input, Side A
1DEN1BVO DEA -15V Voltage B AA 8 V Y Y Y Y Y Y The voltage supplied to the DEA -15V Input, Side B
1DEP0AVO DEA +6V Voltage A AA 8 V Y Y Y Y Y Y The voltage supplied to the DEA +6V Input, Side A
1DEP0BVO DEA +6V Voltage B AA 8 V Y Y Y Y Y Y The voltage supplied to the DEA +6V Input, Side B
1DEP1AVO DEA +15V Voltage A AA 8 V Y Y Y Y Y Y The voltage supplied to the DEA +15V Input, Side A
1DEP1BVO DEA +15V Voltage B AA 8 V Y Y Y Y Y Y The voltage supplied to the DEA +15V Input, Side B
1DEP2AVO DEA +24V Voltage A AA 8 V Y Y Y Y Y Y The voltage supplied to the DEA +24V Input, Side A
1DEP2BVO DEA +24V Voltage B AA 8 V Y Y Y Y Y Y The voltage supplied to the DEA +24V Input, Side B
1DEP3AVO DEA +28V Voltage A AA 8 V Y Y Y Y Y Y The voltage supplied to the DEA +28V Input, Side A
1DEP3BVO DEA +28V Voltage B AA 8 V Y Y Y Y Y Y The voltage supplied to the DEA +28V Input, Side B
1DEPSA DEA Power Supply On/Off A SD 1 Y Y Y Y Y Y 0=Off, 1=On
1DEPSAX DEA Power Supply Enable/Disable A SD 1 Y Y Y Y Y Y 0=Disabled, 1=Enabled
1DEPSB DEA Power Supply On/Off B SD 1 Y Y Y Y Y Y 0=Off, 1=On
1DEPSBX DEA Power Supply Enable/Disable B SD 1 Y Y Y Y Y Y 0=Disabled, 1=Enabled
1DP28AVO DPA Input Voltage A AA 8 V Y Y Y Y Y Y The voltage supplied to the DPA +28V Input, Side A
1DP28BVO DPA Input Voltage B AA 8 V Y Y Y Y Y Y The voltage supplied to the DPA +28V Input, Side B
1DPAMYT DPA -Y Panel Temp PA 8 C Y Y Y Y Y Y DPA -Y Panel Temp. Part Number 311P18-02S7R6.
1DPAMZT DPA -Z Panel Temp PA 8 C Y Y Y Y Y Y DPA -Z Panel Temp. Part Number 311P18-02S7R6.
1DPCPAOC DPA Power Supply Over-Current Protection A SD 1 Y Y Y Y Y Y 0=NO Overcurrent condition detected, 1=Overcurrent condition detected, OCP engaged, power converter shut off.
1DPCPBOC DPA Power Supply Over-Current Protection B SD 1 Y Y Y Y Y Y 0=NO Overcurrent condition detected, 1=Overcurrent condition detected, OCP engaged, power converter shut off.
1DPDBAON DPA Power Supply 28 V On A SD 1 Y Y Y Y Y Y 0=Buss has no power, 1=Buss has power
1DPDBBON DPA Power Supply 28 V On B SD 1 Y Y Y Y Y Y 0=Buss has no power, 1=Buss has power
1DPICACU DPA Input Current A AA 8 A Y Y Y Y Y Y The current supplied to the DPA +28V Input, Side A
1DPICBCU DPA Input Current B AA 8 A Y Y Y Y Y Y The current supplied to the DPA +28V Input, Side B
1DPP0AVO DPA +5V Voltage A AA 8 V Y Y Y Y Y Y The voltage supplied to the DPA +5V Input, Side A
1DPP0BVO DPA +5V Voltage B AA 8 V Y Y Y Y Y Y The voltage supplied to the DPA +5V Input, Side B
1DPPSA DPA Power Supply On/Off A SD 1 Y Y Y Y Y Y 0=Off, 1=On
1DPPSAX DPA Power Supply Enable/Disable A SD 1 Y Y Y Y Y Y 0=Disabled, 1=Enabled
1DPPSB DPA Power Supply On/Off B SD 1 Y Y Y Y Y Y 0=Off, 1=On
1DPPSBX DPA Power Supply Enable/Disable B SD 1 Y Y Y Y Y Y 0=Disabled, 1=Enabled
1HOPRAPR Differential Housing Pressure A AA 8 torr Y Y Y Y Y Y Voltage proportional to the Differential Housing Pressure A
1HOPRBPR Differential Housing Pressure B AA 8 torr Y Y Y Y Y Y Voltage proportional to the Differential Housing Pressure B
1LVDBAON L. V. Enabled A SD 1 Y Y Y Y Y Y 0=Buss has no power, 1=Buss has power
1LVDBBON L. V. Enabled B SD 1 Y Y Y Y Y Y 0=Buss has no power, 1=Buss has power
1MAHCAT Door Close Actuator Temperature A AA 8 C Y Y Y Y Y Y Voltage proportional the temperature on the Close Door Mechanism Actuator A
1MAHCBT Door Close Actuator Temperature B AA 8 C Y Y Y Y Y Y Voltage proportional the temperature on the Close Door Mechanism Actuator B
1MAHOAT Door Open Actuator Temperature A AA 8 C Y Y Y Y Y Y Voltage proportional the temperature on the Open Door Mechanism Actuator A
1MAHOBT Door Open Actuator Temperature B AA 8 C Y Y Y Y Y Y Voltage proportional the temperature on the Open Door Mechanism Actuator B
1MCATATR Door Actuator Transition A SD 1 Y Y Y Y Y Y 0=Door Mechanism NOT in transistion, 1=Door Mechanism in transistion.
1MCATBTR Door Actuator Transition B SD 1 Y Y Y Y Y Y 0=Door Mechanism NOT in transistion, 1=Door Mechanism in transistion.
1MCDRACL Door Close Drive A SD 1 Y Y Y Y Y Y Door Mechanism Close Drive A. 0=Off, 1=On
1MCDRBCL Door Close Drive B SD 1 Y Y Y Y Y Y Door Mechanism Close Drive B. 0=Off, 1=On
1MDBUAON Door Enable A SD 1 Y Y Y Y Y Y 0=Buss has no power, 1=Buss has power
1MDBUBON Door Enable B SD 1 Y Y Y Y Y Y 0=Buss has no power, 1=Buss has power
1MECLACL Door Close A SD 1 Y Y Y Y Y Y 0=Not Closed, 1=Closed
1MECLBCL Door Close B SD 1 Y Y Y Y Y Y 0=Not Closed, 1=Closed
1MEOPAOP Door Open A SD 1 Y Y Y Y Y Y 0=Not Open, 1=Open
1MEOPBOP Door Open B SD 1 Y Y Y Y Y Y 0=Not Open, 1=Open
1MIPWAON Door Input PWR On A SD 1 Y Y Y Y Y Y Door Mechanism Input PWR On A. 0=Off, 1=On
1MIPWBON Door Input PWR On B SD 1 Y Y Y Y Y Y Door Mechanism Input PWR On B. 0=Off, 1=On
1MODRAOP Door Open Drive A SD 1 Y Y Y Y Y Y Door Mechanism Open Drive A. 0=Off, 1=On
1MODRBOP Door Open Drive B SD 1 Y Y Y Y Y Y Door Mechanism Open Drive B. 0=Off, 1=On
1OAHAT Actuator Housing Temp. A PA 8 C Y Y Y Y Y Y open actuator housing. Part Number MF-118.
1OAHBT Actuator Housing Temp. B PA 8 C Y Y Y Y Y Y open actuator housing. Part Number MF-118.
1PDEAAT PSMC DEA PS A Temp PA 8 C Y Y Y Y Y Y PSMC DEA Power Supply A Temp. Part Number MF-118.
1PDEABT PSMC DEA PS B Temp PA 8 C Y Y Y Y Y Y PSMC DEA Power Supply B Temp. Part Number MF-118.
1PIN1AT PSMC Temp PA 8 C Y Y Y Y Y Y PSMC Temp.
1PRDBAON Pressure Transducer On A SD 1 Y Y Y Y Y Y 0=Buss has no power, 1=Buss has power
1PRDBBON Pressure Transducer On B SD 1 Y Y Y Y Y Y 0=Buss has no power, 1=Buss has power
1SSMYT Support Structure -Y Panel Temp PA 8 C Y Y Y Y Y Y Support Structure -Y Panel Temp. Part Number 311P18-02S7R6.
1SSPYT Support Structure +Y Panel Temp PA 8 C Y Y Y Y Y Y Support Structure +Y Panel Temp. Part Number 311P18-02S7R6.
1STAT0ST SW Bilevel Telemetry Bit 0 B 1 Y Y Y Y Y Y General Status - BEP Control Register Bit 2
1STAT1ST SW Bilevel Telemetry Bit 1 B 1 Y Y Y Y Y Y General Status - BEP Control Register Bit 3
1STAT2ST SW Bilevel Telemetry Bit 2 B 1 Y Y Y Y Y Y General Status - BEP Control Register Bit 4
1STAT3ST SW Bilevel Telemetry Bit 3 B 1 Y Y Y Y Y Y General Status - BEP Control Register Bit 5
1STAT4ST SW Bilevel Telemetry Bit 4 B 1 Y Y Y Y Y Y General Status - DPA Hardware Signals
1STAT5ST SW Bilevel Telemetry Bit 5 B 1 Y Y Y Y Y Y General Status - DPA Hardware Signals
1STAT6ST SW Bilevel Telemetry Bit 6 B 1 Y Y Y Y Y Y General Status - DPA Hardware Signals
1STAT7ST SW Bilevel Telemetry Bit 7 B 1 Y Y Y Y Y Y General Status - DPA Hardware Signals
1TSERXT Software Serial Data SD 8 Y Y N N N N Serial Data that comes from the active Backend Processor of the DPA. This data stream is packetized and contains science data, software command verifiers and science housekeeping data. See Appendix B for the Structure of these telemetry it
1VAHCAT Vent Valve Close Actuator Temperature A AA 8 C Y Y Y Y Y Y A voltage proportional the temperature on the Close Vent Valve Actuator A
1VAHCBT Vent Valve Close Actuator Temperature B AA 8 C Y Y Y Y Y Y A voltage proportional the temperature on the Close Vent Valve Actuator B
1VAHOAT Vent Valve Open Actuator Temperature A AA 8 C Y Y Y Y Y Y A voltage proportional the temperature on the Open Vent Valve Actuator A
1VAHOBT Vent Valve Open Actuator Temperature B AA 8 C Y Y Y Y Y Y A voltage proportional the temperature on the Open Vent Valve Actuator B
1VVATATR V.V. Actuator Transition A SD 1 Y Y Y Y Y Y 0=Vent Valve NOT in transistion, 1=Vent Valve in transistion.
1VVATBTR V.V. Actuator Transition B SD 1 Y Y Y Y Y Y 0=Vent Valve NOT in transistion, 1=Vent Valve in transistion.
1VVCDACL V. V. Close Drive A SD 1 Y Y Y Y Y Y 0=Off, 1=On
1VVCDBCL V. V. Close Drive B SD 1 Y Y Y Y Y Y 0=Off, 1=On
1VVCLACL V. V. Close A SD 1 Y Y Y Y Y Y 0=Not Closed, 1=Closed
1VVCLBCL V. V. Close B SD 1 Y Y Y Y Y Y 0=Not Closed, 1=Closed
1VVDBAON V. V. Enable A SD 1 Y Y Y Y Y Y 0=Buss has no power, 1=Buss has power
1VVDBBON V. V. Enable B SD 1 Y Y Y Y Y Y 0=Buss has no power, 1=Buss has power
1VVODAOP V. V. Open Drive A SD 1 Y Y Y Y Y Y 0=Off, 1=On
1VVODBOP V. V. Open Drive B SD 1 Y Y Y Y Y Y 0=Off, 1=On
1VVOPAOP V. V. Open A SD 1 Y Y Y Y Y Y 0=Not Open, 1=Open
1VVOPBOP V. V. Open B SD 1 Y Y Y Y Y Y 0=Not Open, 1=Open
1WRAT Warm Radiator Temp. A PA 8 C Y Y Y Y Y Y Warm radiator +Y warm strap attach point. Part Number MF-118.
1WRBT Warm Radiator Temp. B PA 8 C Y Y Y Y Y Y Warm radiator -Y warm strap attach point. Part Number MF-118.